Due in 3 daysCombined Synopsis/Solicitation
Flow Cytometery Reagents and Supplies (VA-27-00016081)
Department of Veterans Affairs
Key details
- Response deadline
- Nov 27, 2026, 12:00 PM EST (Due in 3 days)
- Solicitation number
- 36C24527Q0070
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- None (full and open competition)
- Small business limit
- Small if no more than 1,250 employees
- Product/service code
- 6550
- Place of performance
- Baltimore, 21201
- Office
- 245-network Contract Office 5 (36c245)
- Posted
- Nov 17, 2026
Description
Effective Date: 01/15/2026 Revision: 03 Description This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01 This solicitation is unrestricted, Full and Open competition. The associated North American Industrial Classification System (NAICS) code for this procurement is 325413 with a small business size standard of 1250 employees. The FSC/PSC is 6550. The Network Contracting Office 5 is seeking to purchase BD FACSLyric Flow Cytometry Reagents/Supplies for the Baltimore VAMC located at 10 N Greene Street, Baltimore, MD 21201. All interested companies shall provide quotations for the following: See Attachment labeled Line Item Template Note: All quantities are estimates Statement of Work BD FACSLyric Flow Cytometry Reagents/Supplies Introduction: Technology: Flow cytometry is a technology that simultaneously measures and then analyzes multiple physical characteristics of single particles, usually cells, as they flow in a fluid stream through a beam of light. The parameters measured include the particle size, granularity or internal complexity, and fluorescence intensity. An optical-to-electronic coupling system determines these characteristics by recording how the cell or particle scatters incident laser light and emits fluorescence. These scatter and fluorescence signals, detected by the instrument, provide information about the cell s size, internal complexity, and relative fluorescence intensity. BD Multisets reagents employ fluorescence triggering, allowing direct fluorescence gating of the lymphocyte population to reduce contamination of lyse-resistant or nucleated red blood cells in the gate. To prepare for flow analysis, a patient s whole blood is added to the reagent, and the fluorochrome-labeled antibodies in the reagent bind specifically to the leucocyte s surface antigens. During acquisition, the stained cells travel past the laser beam and scatter the laser light. The staining pattern of each population, combined with forward-scattered light (FSC) and side-scattered light (SSC) data, can be used to identify which cell populations are present in the patient sample. Photodetectors (Photo iodide & Photomultiplier tubes/PMT) convert the light signals to electronic signals, which are then converted into digital channel numbers for display on a data plot. Scope of work: General: The offeror shall provide to the Veterans Affairs Medical Health Care System at Baltimore VAMC all reagents and supplies for flow cytometry testing in the Hematology section of Pathology and Laboratory Medicine Service. The reagents/supplies will be used for CD4/CD8 count testing and the phenotyping of white blood cells in the leukemia and lymphoma assay using the FACSLyric. QC material and calibration material are used for the detection of voltages and spectral overlap to monitor optimal cytometer settings, checks, and track the daily performance. Term of Agreement: The contract term is for 1 year. Performance Period: 12/03/2026 to 12/02/2027 Reagents: Monoclonal Antibodies for Leukemia and lymphoma diagnostic. The quantity of reagents in this list was based on the data collected from the volume of patients received in 2024 and 2025. The leukemia population was around 300 patients, and the CD4/CD8 T-cell helper testing request was around 3000 patients Place of Performance/Place of Delivery Address: 10 N Greene Street, B…
Full text and attachments are on SAM.gov.
Source: SAM.gov notice b0b1581a6a1441b9a46d407375bc44d0. Last checked Nov 24, 2026. Always confirm details, amendments and attachments on the official notice before you respond.