Skip to content
FedBidAlerts
Due in 1 daySources Sought

NEW | Automated Blood Bank Solid Phase Analyzer and Associated Reagents/Consumables

Department of Veterans Affairs

Key details

Response deadline
Nov 25, 2026, 5:30 PM EST (Due in 1 day)
Solicitation number
36C25927Q0058
Notice type
Sources Sought
Set-aside
None (full and open competition)
Small business limit
Small if no more than 1,000 employees
Product/service code
Q301
Place of performance
Aurora, 80045
Office
Network Contract Office 19 (36c259)
Posted
Nov 13, 2026

Description

This is a Sources Sought Notice NOT a Solicitation. Questions will NOT be answered. All responses should be submitted by November 25, 2026, at 1630 cst. Sources Sought Notice Automated Blood Bank Solid Phase Analyzer and Associated Reagents/Consumables to Rocky Mountain Regional VA Medical Center (RMRVAMC) Disclaimer: This Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. Information Requested from Industry: In response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List. Responses to market research table questionnaire shall be submitted. If this information is not provided, then it will be assumed the entire requirement cannot be met. Description of Requirement: The Department of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for an instrument rental reagent agreement for Automated Blood Bank Solid Phase Analyzer and Associated Reagents/Consumables for the Rocky Mountain Regional VA Medical Center. This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied that the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided. Period of Performance: 04/01/2027 through 03/31/2032 General Requirements: System must be new and in current production. Remanufactured and discontinued models are unacceptable. System must be capable of performing the following test on its solid phase automated analyzer: ABO/Rh Negative Rh Test reflexed to Weak D Antibody Screen, 3 cell screening panel required Antibody Identification of: Anti-E Anti-e Anti-C Anti-c Anti-K Anti-k Anti-D Anti-f Anti-Jka Anti-Jkb Anti-Fya Anti-Fyb Anti-M Anti-N Anti-S Anti-s Anti-P1 Anti-Lea Anti-Leb Anti-Lua Anti-Lub Antigen Phenotyping of: Anti-E Anti-e Anti-C Anti-c Anti-K Direct Antiglobulin Test (DAT) Crossmatching Donor Units with patient samples Ability to handle rouleaux, lipemic, icteric, and hemolyzed specimens. Define the actual hands-on maintenance time required for daily, weekly, monthly, and as needed maintenance. Contractor is to include the analyzer time required to perform each maintenance task and list which tasks are performed at the user level and which tasks are performed at the service level. Provide a comprehensive quality control (QC) program which includes the following options: QC files that can be edited or corrected for errors On-board quality control data storage and reporting capabilities DVD for data archive Ability to alert operator of QC failures Daily QC performance within 30 minutes System must be able to record and display temperature records. System must contain an automated cell washer with a wash cycle of less than 5 minutes and allows for processing of lipemic or icteric samples. System must have a centrifuge with automatic load/unload. System must contain a printer and necessary replacem…

Full text and attachments are on SAM.gov.

Source: SAM.gov notice f7ba8da853564af6a36ca00b9a898459. Last checked Nov 24, 2026. Always confirm details, amendments and attachments on the official notice before you respond.