Skip to content
FedBidAlerts
Due in 13 daysSources Sought

Uscgc Hickory (Wlb-212) Drydock Repair FY27

Department of Homeland Security · US Coast Guard

Key details

Response deadline
Dec 7, 2026, 11:00 AM EST (Due in 13 days)
Solicitation number
70Z08527RIBCT270001087
Notice type
Sources Sought
Set-aside
None (full and open competition)
Small business limit
Small if no more than 1,300 employees
Product/service code
J999
Place of performance
Hawaii
Office
Cg-sea-c22
Posted
Nov 17, 2026

Description

This is a SOURCES SOUGHT NOTICE / REQUEST FOR INFORMATION; not a pre-solicitation notice or solicitation for proposals/quotations. The applicable NAICS Code is 336611, Ship Building and Repairing, and the size standard is 1,300 employees. REQUIREMENT: This notice is issued by the U.S. Coast Guard, Surface Forces Logistics Center, and Alameda, CA to identify sources capable of providing the following: Contractor shall provide all necessary labor, materials, services, equipment, supplies, power, accessories, special tools and such other things as are necessary to perform DRYDOCK maintenance to the U.S. Coast Guard Cutter, USCGC HICKORY (WLB 212). USCGC HICKORY (WLR-WLB 212) DRYDOCK AVAILABILITY FY27. ANTICIPATED NAICS CODE/SIZE STANDARD: The applicable NAICS Code is 336611, Ship Building and Repairing and the size standard is 1,300 employees. GEOGRAPHICAL RESTRICTION: YES, SUBJECT TO U.S COAST GUARD DISTRICT 14 - HAWAII MILITARY CONSIDERATION MEMORANDUM PLACE OF PERFORMANCE: Contractor’s Facility DESCRIPTION OF WORK: This requirement is for the contractor to provide all necessary facilities, materials, equipment, personnel, and other such things necessary to perform Dry-dock repairs to the U.S. Coast Guard Cutter (USCGC) HICKORY (WLB 212). This vessel’s homeport is Coast Guard Station Apra Harbor Guam 96915. All work is to be performed at the Contractor’s facility. The required performance period is 84 days. The performance period is 15 July 2027 – 07 October 2027 to accommodate Coast Guard cutter operational needs. Description: This Dry Dock will consist of approximately one hundred and ten (110) work items, not limited to: hull plating ultrasonic testing, underwater body preserve, propeller removal and inspect, propulsion shaft remove, inspect and reinstall, rudders remove, inspect, reinstall and preserve, construction deck 100% preserve, tanks clean and inspect, and boat davit inspect. ITEM DESCRIPTION D-001 Fire Prevention Requirements «TYPE» D-002 Hull Plating, U/W Body, Inspect D-003 Hull Plating, U/W Body, Ultrasonic Testing O-004 U/W Body, Preserve, 100 percent O-005 U/W Body, Preserve, Partial, Condition A O-006 U/W Body, Preserve, Partial, Condition B O-007 U/W Body, Preserve, Partial, Condition C D-008 Hull Plating, Freeboard, Ultrasonic Testing O-009 Hull Plating Freeboard, Preserve, 100 Percent O-010 Hull Plating Freeboard, Preserve, Partial O-011 Hull Plating Freeboard (Buoy Port Areas), Preserve O-012 Hull and Structural Plating, General, 10.2 lbs. Steel, Renew O-013 Hull and Structural Plating, General, 12.75 lbs. Steel Plate, Renew O-014 Hull and Structural Plating, General, 15.3 lbs. Steel Plate, Renew O-015 Hull And Structural Plating, General, 20.4 lbs. Steel Plate, Renew O-016 Hull and Structural Plating, General, 7.5 lbs., 3/16 in. Steel Plate, Renew O-017 Hull and Structural Plating, General, 7.65 lbs. Steel Plate, Renew O-018 Hull And Structural Plating, General, Cracked Steel Welds, Repairs O-019 Hull and Structural Plating, General, Degraded Weld, Steel, Repair D-020 Cathodic Protection, Zinc Anodes, Renew D-021 Impressed Current, Cathodic Protection System and Reference Cell Anodes, Renew D-022 Impressed Current Cathodic Protection System, Inspect and Maintain D-023 Appendages, U/W, Leak Test O-024 Appendages, U/W, Internal, Preserve O-025 Chain Locker, Preserve, 100 Percent D-026 Voids, Non-Accessible, Leak Test O-027 Voids, Non-Accessible, Internal Surfaces, Preserve O-028 Accessible Voids, Preserve, 100 Percent O-029 Accessible Void(s), Preserve, Partial D-030 Propulsion Shaft Fairwaters And Rope Guards, Inspect D-031 Grey Water Holding Tanks, Clean and Inspect O-032 Tanks, Grey Water Holding, Preserve, 100 Percent O-033 Tanks, Grey Water Holding, Preserve, Partial D-034 Sewage Holding Tanks, Clean and Inspect O-035 Tanks (Sewage Holding), Preserve, 100 percent O-036 Tanks (Sewage Holding), Preserve, Partial D-037 Sewage Piping, Clean and Flush D-038 Tanks, Potable Water, Clean and Inspect O-039 Tan…

Full text and attachments are on SAM.gov.

Source: SAM.gov notice 8c9f2553cd6c47639fde59725ab3c740. Last checked Nov 24, 2026. Always confirm details, amendments and attachments on the official notice before you respond.