USCGC Polar Star 1000KW Generator Rental

Department of Homeland Security · US Coast Guard

Key details

Response deadline
Nov 24, 2026, 11:00 AM EST (Due in 6 hours)
Solicitation number
70ZU0227Q0001264
Notice type
Combined Synopsis/Solicitation
Product/service code
W061
Place of performance
Jbphh, Hawaii, 96860
Office
Cg-sea-c22
Posted
Nov 23, 2026

Description

RENTAL SERVICES FOR 1,000Kw GENREATOR Background USCGC POLAR STAR is preparing to get underway while a Ship Service Diesel Generator is unavailable. To sustain required cutter capability, the United States Coast Guard requires temporary portable electrical-generation capability, including the equipment and accessories necessary to connect the generator to the cutter's Viking International shore-tie connections. The rented generator will be placed aboard the cutter and used as temporary shipboard electrical generation during the rental period. Scope. Provide rental and delivery of one portable generator package meeting the requirements below to the delivery location identified in this SOW for an anticipated rental period of approximately six months. The contractor shall also retrieve the generator package from the pier at the end of the rental period. Minimum power rating 750 kW (prime), maximum 1000 kW, 450/480 VAC, 3-phase, 3-wire power. Generator must be able to withstand 1.5 times rated current for up to 30 seconds. Minimum generator insulation class F. Electrically operated generator circuit breaker, of either insulated-case or power circuit breaker type, must be installed for protection of the generator and the connecting power cable, with electronic trip unit capable of long-, short-, and instantaneous tripping. Circuit breaker must be rated for minimum 45 kA asymmetric interrupt rating. Protection settings must be set for generator protection in accordance with American Bureau of Shipping (ABS) Marine Vessel Rules (MVR) 2025 Part 4, Chapter 8, Section 2, Paragraph 9.11 (4-8-2/9.11). Specifically: Overload protection Short-circuit protection Thermal damage protection Reverse power protection Prime mover shutdown Undervoltage protection 300’ of cable rated for 115% of generator maximum current in 40 deg C ambient, minimum 90 deg C rated cable. Cable must be rated for flexible service, single conductors no larger than 4/0 for purposes of installation on the ship. Generator must be enclosed in a standard 30-foot or 40-foot shipping container. Exact specifications and dimensions must be provided in the proposal. Internal lighting, and all necessary control systems for operators to manage the system inside the container must be installed. Generator engine must be electrically started. Battery capacity must be sufficient when fully charged for at least 10 starts. Switchgear and bus bar must be braced for asymmetric short-circuit carrying capacity of the generator. The container must include a radiant cooling system capable of maintaining generator temperature in a range of ambient temperatures. The generator must be capable of operation in ambient temperatures of 15 degrees F to 100 degrees F. The generator fuel system must be capable of being refueled while on-line, may be connected to ship’s power for heaters and battery chargers, but must not require any other fluid or system inputs from the ship. The generator and container must be suitable for marine use on board a ship, and the container must have suitable protection from rain, salt spray, low-level flooding from waves, snow, ice, and operating angles up to 15 degrees. It must have physical connections for attachment on deck, and external grounding points for grounding container to the hull. Generator must not have neutral grounding, and any installed ground protection features must be disabled. Grounding of the container will be installed by the Government. Fuel tank must be suitable for generator operation at 50% prime rated power without refueling for 24 hours. Excitation system must not require external power source or field flashing prior to operation. Heaters must be provided to support generator operation within 15 minutes. Exhaust system must include suitably sized spark arrestor and silencer. Generator total harmonic distortion must be less than 3%. Tasks. The contractor shall provide operator and maintenance instructions necessary for the Government to operate …

Full text and attachments are on SAM.gov.

Source: SAM.gov notice d2afbcaa6f134ac8a526a16a2c154531. Last checked Nov 24, 2026. Always confirm details, amendments and attachments on the official notice before you respond.